High Performance Intelligences Underground Cable Path Detection Pipeline Survey Depth Measurement of Professional Instruments
Basic Info
Model NO. | ZXPD3000 |
After-sales Service | Provide lifelong after-sales service |
Warranty | 1 Year |
Certification | CE, ISO |
Condition | New |
Customized | Customized |
Alarm Form | LCD |
Output frequency | 640Hz, 1280Hz, 10kHz, 33kHz, 82kHz, 197kHz. |
Output power | 10W, 10 levels adjustable |
Volume | transmitter 280*220*90mm, receiver 680*120*277mm |
Charger | input AC100~240V, 50/60Hz, output DC8.4V, 2A |
Mass | 2.3kg for transmitter and 2.0kg for receiver. |
Operating conditions | temperature: -10-40C, humidity 5-90%RH, |
Altitude | <4500m |
Transport Package | Carton/Wooden Case |
Specification | 300*270*200 mm |
Trademark | GDZX |
Origin | Hubei |
Production Capacity | 500 Pieces/Month |
Product Description
Intelligent Underground Pipeline Detector With Ground Fault Finding
ZXPD3000 Underground pipeline detector is a high-performance underground metal pipeline detection system consisting of a signal transmitter and a receiver. It can be used for path detection, pipeline survey and depth measurement of metal pipelines and underground cables. It can be identified with a variety of optional accessories. As well as the search for pipe insulation damage and some types of cable faults.
Technical Indicators
Transmitter | Output frequency: 640Hz, 1280Hz, 10kHz, 33kHz, 82kHz, 197kHz |
Output power: 10W, 10 levels adjustable, automatic real-time impedance matching. | |
Direct connection output voltage: 150Vpp. | |
Receiver | Active detection frequency: 640Hz, 1280Hz, 10kHz, 33kHz, 82kHz, 197kHz. |
Power frequency passive detection frequency: 50Hz/60Hz and 250Hz/300Hz (user configurable). | |
Radio frequency passive detection frequency band: the center frequency is 10kHz, 33kHz, 82kHz respectively. | |
Volume | Transmitter 280×220×90mm;Receiver 680×120×277mm |
Weight | 2.3kg for transmitter and 2.0kg for receiver. |
Charger | Input AC100~240V, 50/60Hz;Output DC8.4V, 2A. |
Operating conditions | Temperature: -10ºC-40ºC;Humidity:5-90%RH;Altitude <4500m |
1. Transmitter
1) Output mode: direct output, radiation induction, caliper coupling (optional), fault-checking booster (optional).
2) Output frequency: 640Hz, 1280Hz, 10kHz, 33kHz, 82kHz, 197kHz.
3) Output power: 10W, 10 levels adjustable, automatic real-time impedance matching.
4) Direct connection output voltage: 150Vpp.
5) Overload and short circuit protection.
6) Man-machine interface: 320×240 dot matrix liquid crystal display.
7) Built-in battery: 4 18650 lithium ion batteries, nominal 7.4V, 6.8Ah.
2. Receiver
1) Input mode: built-in receiving coil, flexible caliper (optional), stethoscope (optional), fault checking A-frame (optional).
2) Receiving frequency:
Active detection frequency: 640Hz, 1280Hz, 10kHz, 33kHz, 82kHz, 197kHz.
Power frequency passive detection frequency: 50Hz/60Hz and 250Hz/300Hz (user configurable). Radio frequency passive Detection frequency band: the center frequency is 10kHz, 33kHz, 82kHz respectively.
3) Pipeline detection mode: broad peak method, narrow peak method, sound valley method.
4) Cable identification mode: flexible caliper (optional) intelligent identification and current measurement, stethoscope (optional) identification.
5) Man-machine interface: 320×240 dot matrix liquid crystal display.
6) Built-in battery: 2 18650 lithium ion batteries, nominal 7.4V, 3.4Ah.
3. Other
1) Volume: transmitter 280×220×90mm, receiver 680×120×277mm.
2) Mass: 2.3kg for transmitter and 2.0kg for receiver.
3) Charger: input AC100~240V, 50/60Hz, output DC8.4V, 2A.
4) Operating conditions: temperature: -10ºC-40ºC, humidity 5-90%RH, altitude <4500m.4. Configuration table
About GDZX
Shipping and packaging
Features
1. Compass and direction display: visually display pipeline position and left-right direction.
2. Tracking right and wrong prompts: current direction measurement, tracking right and wrong prompts, eliminating adjacent line interference (partial frequencies).
3. Depth and current measurement, can display signal strength history curve.
4. Fully digital high-precision sampling processing: stable and reliable, ultra-high sensitivity, extremely narrow receiving passband, strong anti-interference ability, and can fully suppress the power frequency and harmonic interference of adjacent running cables and pipelines.
5. Running cable detection: high-performance launch calipers, coupling output signals to running cables.
6. Cable/pipeline identification: The flexible caliper (optional accessory) is easy to use, and the identification result is clearly given; the stethoscope (optional accessory) can be used when the caliper is inconvenient to use.
7. Ground fault finding: the booster (optional) can increase the output voltage to 1000V, and the A-frame (optional) can be used to locate the damaged point of the pipeline to the ground insulation without zero adjustment. The arrow indicates the direction of the fault point.
8. Multiple detection frequencies: active detection and passive detection.
9. Multiple signal output modes of the transmitter: direct connection output, clamp coupling, radiation induction.
10. Transmitter digital amplifier power output, automatic impedance matching, automatic protection.
11. Built-in removable large-capacity lithium-ion battery, automatic shutdown under voltage, and automatic shutdown without operation for a long time.
12. The cabinet is beautiful and firm, lightweight and portable.