banner
Products
Instant delivery
Dosimetry for Linear Accelerator

Dosimetry for Linear Accelerator

dosimetry for linear accelerator dosimetry for linear accelerator (Six working modes) Model: MCS-2000I-6 Electric Surgic;
Basic Info
Model NO. MCS-2000I-6
Medical Equipment Dosimetry for Linear Accelerator
Six Working Modes Cut,Bloodless Cut,Fulguration,Forced Coag,Soft Coa
Monopolar Can Be Controlled by Hand or Foot
Bipolar Can Be Controlled by Foot Only
Microcomputer Control Both Monopolar and Bipolar
Precise Power Control an Be Used for All General Surgical Procedures
Touch Control Panel Three-Way Power Output
Bipolar Coagulation 1W~50W(70W)( Load 100Ω)
Power Consumption <=880va
Usage Dosimetry for Linear Accelerator
Transport Package Export Standard Packaging for Air and Sea
Trademark Mecan
Origin China (Mainland) Guangdong
Production Capacity 5000
Product Description

dosimetry for linear accelerator

dosimetry for linear accelerator

(Six working modes)

Model: MCS-2000I-6

Electric Surgical Unit Features:

1. Microcomputer control.

2. Both monopolar and bipolar. Monopolar can be controlled by hand or foot. Bipolar can be controlled by foot only.

3. Precise power control, can be used for all general surgical procedures.

4. Touch control panel, three-way power output, with different audible and visual indication during the process of outputting.

5. Automatic performance check during startup and Polar plate test.

6. Power Peak System provides surgeons with improved performance at Lower power settings, minimizing the risk of tissue damage.

7. Full floating output system protects patient from tissue damage caused by low frequency current.

8. Automatic compensation system ensures the stable output and minimizes power consumption. Suitable for underwater surgery, including fibrin-rich tissue cutting.

9. CVREM contact quality monitoring system which substantially reduces the risk of burns under the patient return electrode. When patient plate and skin are not well contacted, the system will automatically stop the output and sound alarm.

10. Pencil Remoting Output. Surgeon can change the power output by remoting control electrosurgical pencil.

Electric Surgical Unit Technical Specifications:

Power: 220V±22V(110V±11V), 50Hz±1Hz

Operating frequency: 360~460kHz

Power rating: 880VA±10%

Six working modes:

Monopolar Cut:

a) Cut (pure cut):

1W~300W( Load 500Ω), apply to the operation of any tissue.

b) Bloodless cut (Blend1):

1W~250W(Load 500Ω), apply to the surgery of any tissue, proving a good coagulation effect while cutting.

c) Fulguration (Blend2):

1W~150W(Load 500Ω), apply to endoscopic surgery, providing a good homeostasis effect while cutting.

Monopolar Coag:

d) Coagulation1(Forced coag):

1W~150W( Load 500Ω), apply to ordinary open surgery, deep tissue coagulation layer, has excellent homeostasis effect.

e) Coagulation2(Soft Coag):

1W~120W( Load 500Ω), suitable for endoscopic and other fine tissue surgery with fast contact coagulation.

Bipolar:

f) Bipolar coagulation:

1W~50W(70W)( Load 100Ω), when tissue reach a good coagulation effect, output power slow down, making a good homeostasis effect.

Power Consumption: <=880VA(Cutting function 300W, Bipolar coagulation function 50W output).

Packing list:

Name

Quantity

Mainframe

1set

Remoting control pencil

1piece

Electrosurgical pencil

5pieces

Electrosurgical pad

10 pieces

Electrosurgical pad cable

1piece

Foot switch

1set

Tip clean sponge

1piece

Bipolar forceps and its cable

1set

Fuse

3pieces

Power cord

1piece

Operating manual

1book

Dimension:

G.t 14kg

Size: 59*49*34cm

Dosimetry for Linear Accelerator


Welcome to contact MeCan Medical for dosimetry for linear accelerator
Send inquiry